PLC or VFD: where the automation fault usually lives
Most machine panels combine PLC control logic with VFD power electronics. When a machine stops, telling us which side the fault is on gets you a faster, cheaper repair.
Signs the fault is in the drive
- The drive display shows an alarm or trip.
- The motor hums, jerks or stops while the PLC still shows the run command on.
- Faults appear at a particular speed or load.
Signs the fault is in the PLC or control circuit
- The drive is healthy and ready, but never receives a run command.
- The PLC shows a fault bit, a stopped program or a red error LED.
- Sequences go wrong: steps skipped, interlocks not released, timers not finishing.
A quick check anyone can do
Look at the drive's digital input status while the machine should be running. If the run input is off, look upstream at the PLC output, relay or wiring. If it is on and the drive still does not run, the drive or its parameters need attention.